Pertzel Lab · Jack's research practice within J & Co Season 1 · October to November 2026

Pertzel Lab · Season 1 · Announcement

Can a public AI model read an ECG as well as the doctors who labelled it?

I'm starting a one-person research lab, and this is the first thing I'm doing with it.

There's a published AI model called ECGFounder that was trained on ten million ECGs. Its authors say it can read a 12-lead ECG and pick out 150 different things, from a normal rhythm to signs of an old heart attack. The model is free, the weights are public, and it runs on my laptop. I've already run it on ten hospital ECGs this week and watched it answer.

Twelve ECG traces in a grid, labelled I, II, III, aVR, aVL, aVF and V1 to V6, ten seconds each
Figure A. What the model sees. PTB-XL record 1: twelve leads, ten seconds, 500 samples a second, labelled by cardiologists as normal ECG, sinus rhythm, low QRS voltage. Data: PTB-XL v1.0.3 (Wagner et al., 2020), PhysioNet, CC BY 4.0.

What I'm doing over the rest of this six-week season (it ends on 22 November) is simple to say. First, I take the hospital dataset the authors scored their model on (PTB-XL, about 22,000 ECGs read by cardiologists) and check that I get the number they published. That's a replication: does their claim hold up when someone outside their lab runs it? Then I take a dataset the model has never seen: ECGs recorded during surgery, with stretches where every heartbeat was checked by anaesthesiologists, released this year. And I ask the real question. When this model leaves home, how much worse does it get? And when it's confident, should you believe it?

A single ECG trace over ten seconds with eight marked beats: seven blue dots on normal beats and one gold dot on a taller ventricular ectopic beat
Figure B. The data it has never seen. VitalDB case 1001, lead II, ten seconds during surgery, every beat labelled by a classifier and then checked by at least two anaesthesiologists; the gold dot is a ventricular ectopic beat. Data: VitalDB Open Dataset, CC BY-NC-SA 4.0 (Lee et al., Sci Data 2022, doi:10.1038/s41597-022-01411-5) and the VitalDB Arrhythmia Database, PhysioNet, CC BY 4.0 (Eun et al., 2026, doi:10.13026/axd6-wm13). This figure is a non-commercial derivative shared under the same licence.

Why do I care? Partly because it's a bit of fun. I get to do cutting-edge data analysis on real data with tools that didn't exist two years ago. Partly because I'm really passionate about health and medicine. Partly because, from what I can see, no one seems to publish this kind of measurement. Models get trained and announced; what happens to them on new data, in new hospitals, on new devices, mostly goes unreported. If you read ECGs, you get an outside check on a model people are already using. If you build with cheap sensors, you get the answer to whether a fifty-dollar board plus a public model means anything. That's the gap I want to work in. And partly because it feels like, with the tools around now, one person can genuinely be a research lab. That's just cool and exciting. And being able to share what I find with anyone in the world is incredible.

After this season, the plan is to bring it to my own chest. A chest strap you can buy, a small sensor board wired up to a microcontroller by me, and the same model run on my own recordings, so we can see how far a hospital-grade model travels to a sensor that costs fifty dollars. That's Season 2.

A table of ten records with the cardiologists' codes and the model's two strongest guesses; record 8 is highlighted
Figure C. Ten records in, ten answers out. The published model run unchanged on the first ten PTB-XL records, Tuesday. Eight normal ECGs it called normal. One normal ECG with a slow heart it called slow. One old heart attack it scored normal ECG 0.97 and abnormal ECG 0.91, with its infarct label at 0.02. That row is why this is worth doing. A smoke test, not a result. Model: ECGFounder (Li et al., NEJM AI 2025, MIT licence).
Figure C as text
The first ten PTB-XL records through ECGFounder, run unchanged; probabilities from runs/s1-w1-smoke/predictions.csv
RecordCardiologists' codesModel's two strongest guesses
1NORM, LVOLT, SRsinus rhythm 1.00 · normal sinus rhythm 1.00
2NORM, SBRADsinus bradycardia 1.00 · marked sinus bradycardia 0.99
3NORM, SRsinus rhythm 1.00 · normal sinus rhythm 1.00
4NORM, SRnormal sinus rhythm 1.00 · sinus rhythm 1.00
5NORM, SRsinus rhythm 1.00 · normal sinus rhythm 1.00
6NORM, SRsinus rhythm 1.00 · normal sinus rhythm 1.00
7NORM, SRsinus rhythm 1.00 · normal sinus rhythm 1.00
8IMI, ABQRS, SRnormal sinus rhythm 1.00 · sinus rhythm 1.00
9NORM, SRsinus rhythm 1.00 · normal sinus rhythm 1.00
10NORM, SRsinus rhythm 1.00 · normal sinus rhythm 1.00

What I'll put out, by the end of November: the code, so anyone can rerun it; a short paper on a preprint server; the figures; and the week-by-week record of how it went, including what broke.

What I don't know yet: whether the model holds up against what the anaesthesiologists checked, or whether it quietly falls apart on data it wasn't trained on. Whether my own cheap recordings will be good enough to test it on at all. And whether anyone will find this interesting. I'm going to try anyway.

One rule for everything I post here I'll report what the data and the model show, never what it means for anyone's health. That's a different job, and not mine yet.